The FLD-TSP10 (10-inch) and FLD-TSP7 (7-inch) are high-performance touchscreen controllers designed for powering and interfacing with Naftosense brand of monitoring modules. Communication with these modules is based on Naftosense long-range ERBUS proprietary bus. These controllers are offered in a IP54/NEMA 3S water-resistant wall-mounted enclosure, to be installed in control rooms and other remote locations where dripping water might be potentially present. The touchscreens are impedance-based and have Gorilla Glass on the touch panel, making for an extremely rugged design for any solution.
The primary use of the controller is to monitor up to three zones with long detection strings for hydrocarbons, alcohols, solvents, or conductive liquids of up to 9800ft (3000 m) each. Each zone on the controller is capable of powering and communicating with up to 25 Naftosense monitoring modules. The communication protocol permits robust and reliable operation even in case of partial failure of the circuit of monitoring modules. Each individual monitoring module can be connected to several independent sensors and provides true multi-leak capability.
Utilize your existing network when integrating a Naftosense leak detecting system. Compatible with any wireless and wired system via a host of standard communication protocols:
| Model | View | Description |
| FLD-MXM (all versions) | ![]() |
Long-range multiplexed Monitoring module for monitoring of up to 8 sensing cables or probes for detecting hydrocarbons in both indoor and outdoor environment. Maximum length of sensor string per acquisition module: 400 ft (120 m) |
| FLD-FBS (all versions) | ![]() |
Long-range monitoring module with flexible wiring options and programmable detection algorithms for monitoring of up to 8 sensors for detecting hydrocarbons in both indoor and outdoor environment. Maximum length of sensor string per acquisition module: 400 ft (120 m) |
| Technical Data | |
| Fire Rating | Non-flammable, UL508 approved |
| Ingress Rating | IP54/NEMA 3S - indoor use only |
| Operating Temperature Range | 32°F to 122°F (0°C to 50°C) |
| Power Supply Input | 100-240VAC or 24VDC |
| Maximum Length of Cable | Accumulated Length of Sensor and Leader Cable: 2 miles (3.2 km) |
| Power Consumption | 18.5W maximum |
| Mounting | Wall-mounted |
| Warranty | 10 years |
Warning! The FLD-TSP10 & FLD-TSP7 monitoring panels are housed in a UL508 approved enclosure and are provided with a cULus Listed display controller. It shall be installed by qualified personnel in accordance with the relevant local regulations for electrical safety.
| Product Codes | |
| FLD-TSP-7 | Single-channel monitoring panel for up to 25 Naftosense acquisition modules for detecting liquid leaks, with Modbus RTU/TCP and 2 SPDT relay outputs - wall-mounted, with 7-in HMI and loopback |
| FLD-TSP-10 | Dual-channel monitoring panel for up to 50 Naftosense acquisition modules for detecting liquid leaks, with Modbus RTU/TCP and 4 SPDT relay outputs - wall-mounted, with 10-in HMI and loopback |
| FLD-TSP-7-19 | Single-channel monitoring panel for up to 25 Naftosense acquisition modules for detecting liquid leaks, with Modbus RTU/TCP and 2 SPDT relay outputs - 19-in rack-mounted, with 7-in HMI and loopback |
| FLD-TSP-12-2X19-x | Redundant multi-channel monitoring panel for up to 200 Naftosense acquisition modules for detecting liquid leaks, with Modbus RTU/TCP and 2 SPDT relay outputs - 19-in rack-mounted, with dual 12-in HMI and automatic redundancy switching |