The FLD-DHSC is a high-performance passive hydrocarbon/solvents detector designed specifically for detecting the unwanted presence of a wide range of liquid hydrocarbons or organic solvents. The FLD-DHSC has two sensor wires multiplexed cable provides quick reaction to the target liquids and can be used in outdoor environment without being affected by exposure to water.
The detected fluids are primarily gasoline, diesel, jet fuel, acetone/MEK, methanol, ethanol, esters, transformer oils, etc. The FLD-DHSC sensor cable is offered as factory-assembled modular sensor with heavy-duty waterproof connectors (model-C), or as fixed-length multi-section encapsulated sensor string with oil- resistant 10-ft leader cable (model -L).
The sensor is specially engineered for reliable operation in both indoor and outdoor conditions. The waterproof connectors of -C model allow the sensor to be temporarily immersed in water. The encapsulated -L model is designed for long-term immersion in water in demanding outdoor conditions. The semi-conductive sensor material is extremely durable and can withstand exposure to temperatures more than 212°F (100°C). The sensor cable is UV resistant, anti-termite and anti-rodent and can be used in tropical applications.
Typical Detection Time at 68°F (20°C) | |
Unleaded Gasoline | 1 minute 20 seconds |
Diesel/Jet Fuel | 3 minutes |
Methanol/Ethanol | 5 to 7 minutes |
Acetone/MEK | 6 to 8 minutes |
Motor/Silicone Oils | 12 to 25 minutes |
Technical Data | |
Operating Life | 10-year warranty expected life 20+ years (materials tested in natural aging conditions) |
Weight | 1.3oz / ft (120 g/m maximum) |
Fire Rating | Non-flame propagating |
Connector Ingress Rating | IP68 - suitable for outdoor/direct burial |
Operating Temperature Range | -40°F to 185°F (-40°C to +85°C) |
Recommended Maximum Section Length | 50 ft (15 m) |
Hazardous Locations Classification | IS/ I/ 1/ ABCD/ T4 ; I/ 0/ AEx/ ia IIC T4 ; Class I, Zone 0, Ex ia T4 Class I, Div. 1, Groups A,B,C,D; T4 II 1 G Ex ia IIC T4 Ga |
Warranty | 10 years |
Warning! The sensor cable FLD-DHSC shall only be used with the Naftosense brand monitoring modules. Use with other applications will lead to unpredictable performance and unexpected results. For performance metrics, please contact Naftosense.
Product Codes | |
FLD-DHSC-TL-C-10 | Modular Multiplexed Sensor cable for hydrocarbons/solvents – up to 2 sections – length of 10 ft (3 m) |
FLD-DHSC-ML-C-10 | Modular Multiplexed Sensor cable for hydrocarbons/solvents – up to 4 sections – length of 10 ft (3 m) |
FLD-DHSC-TL-C-25 | Modular Multiplexed Sensor cable for hydrocarbons/solvents – up to 2 sections – length of 25 ft (7.5 m) |
FLD-DHSC-ML-C-25 | Modular Multiplexed Sensor cable for hydrocarbons/solvents – up to 4 sections – length of 25 ft (7.5 m) |
FLD-DHSC-TL-C-50 | Modular Multiplexed Sensor cable for hydrocarbons/solvents – up to 2 sections – length of 50 ft (15 m) |
FLD-DHSC-ML-C-50 | Modular Multiplexed Sensor cable for hydrocarbons/solvents – up to 4 sections – length of 50 ft (15 m) |
FLD-DHSC-TL-Lx-10* | Encapsulated Sensor cable for hydrocarbons/solvents with 10 ft (3 m) leader cable – length of 10 ft (3 m) |
FLD-DHSC-ML-Lx-10* | Encapsulated Sensor cable for hydrocarbons/solvents with 10 ft (3 m) leader cable – length of 10 ft (3 m) |
FLD-DHSC-TL-yyy* | Bulk Sensor cable for hydrocarbons/solvents – up to 2 sections |
FLD-DHSC-ML-yyy* | Bulk Sensor cable for hydrocarbons/solvents – up to 4 sections |
*x in the product codes above denotes the number of sections per sensor string of -L model – up to 2 for FLD-DHSC-TL and up to 4 for FLD-DHSC-ML
*yyy in the product codes above denotes the length in feet for the bulk sensor cable. Maximum length of bulk sensor cable: 820 ft (250 m)