FLD-SSMH-DS Control Module for Single Sensor Leak Detection

The FLD-SSMH-DS is designed for smaller leak detection applications where a single sensor under 100 ft is used. The DIN-rail mounted controller is ready to be mounted in your NEMA rated enclosure. The maximum sensor length is limited to 100ft/30m per FLD-SSMH.

For hazardous locations applications, the sensor cable FLD-HSC or FLD-O2W-SP sensor probe will be wired to the sensor module through a Zener barrier, with FLD-SSMH module installed in an area approved enclosure.

Please contact Naftosense for additional information.

Features and Benefits

  • Detects reliably all North-American crude oils at very low temperatures
  • Real-time transmission of cable contamination
  • Dynamic tracking of the sensor contamination
  • Adjustable alarm threshold
  • Very wide operating temperatures range
  • Able to detect the vapors diffused in the soil after spill from underground pipes
  • 10-year warranty

Typical Applications

  • Leak detection in Oil & Gas facilities
  • Detection of leaking fuel from airport hydrant systems, military, and custody transfer installations in harsh outdoor, demanding environmental conditions
  • Leak detection in refineries, tank farms, mainline pipe sections, or repair sites
  • Leak detection in refineries, tank farms, block valves, mainline pipe sections
  • Leak detection in downstream and fuel retail facilities

Communication Made Easy

Utilize your existing network when integrating a Naftosense leak detecting system. Compatible with any wireless and wired system via a host of standard communication protocols:

  • 0-10V
  • 4-20mA
  • Dry Contact
  • Modbus RTU (RS-485)
  • TCP/IP (with protocol converter)

Agency Approvals

  • Class 2 device, tested for compliance with ANSI/UL 61010-1

TECHNICAL INFORMATION

Typical Detection Time at 68°F (20°C) with FLD-HSC Sensor Cable
Unleaded Gasoline 1 minute 20 seconds
Diesel 2 minutes
Jet Fuel 2 minutes
WTI/WTS 6 to 7 minutes
Dilbit AWB 11 to 12 minutes
Bunker C oil 45 to 55 minutes

Technical Data
Dimensions 1.42" x 3.35" x 2.28" (36 x 85 x 58 mm) - 2-module DIN
Weight 0.5 lb. / (225 g)
Fire Rating UL94-HB
Ingress Rating Panel: IP10/NEMA 1 - indoor use only
Operating Temperature Range -13°F to 149°F (-25°C to 65°C)
Power Supply Voltage Range 12 - 24 VDC Class 2 Circuit / 24 VDC only for FLD-SSM-H420
Battery Operating Life 10 years minimum
Maximum Length of Cable Sensor Cable FLD-HSC: 100 ft (30 m)
Leader Cable (AWG22 min): 1000 ft (300 m)
Power Consumption 80mA maximum
Mounting DIN-rail mounted inside electric cabinet or suitable enclosure
Warranty 10 years

Attention! FLD-SSM panel is approved by accredited certification organization for worldwide safe use in both residential and industrial environments. For additional information, please contact Naftosense.

Product Codes
FLD-SSM-HR2 Monitoring module for a single passive sensor cable or probe for detecting non-polar liquids, with 2 SPDT relays outputs
FLD-SSM-HMBR2 Monitoring module for a single passive sensor cable or probe for detecting non-polar liquids, with Modbus RTU and 2 SPDT relay outputs
FLD-SSM-HR2-420 Monitoring module for a single passive sensor cable or probe for detecting non-polar liquids, with 3-wire current loop 4-20mA output and 2 SPDT relay outputs
FLD-SSM-HR2-010 Monitoring module for a single passive sensor cable or probe for detecting non-polar liquids, with 0-10V output and 2 SPDT relay outputs